Skip to main content

Table 2 Half maximal effective concentration (EC50) and limit of detection (LOD) values of antibodies that were determined from the titration curves of sandwich ELISA

From: Generation of a recombinant antibody for sensitive detection of Pseudomonas aeruginosa

Antigen

Capturing antibody

Detecting antibody

EC50 (CFU/mL)

LOD (CFU/mL)

UCBPP-PA14

Monoclonal antibody (mAb)

Polyclonal antibody (pAb)

1.43 ± 0.44 × 106

1.39 × 105

UCBPP-PA14

pAb

mAb

4.62 ± 2.80 × 106

8.50 × 102

UCBPP-PA14

Recombinant antibody (rAb)

pAb

4.10 ± 1.68 × 106

3.34 × 104

UCBPP-PA14

rAb

mAb

2.00 ± 0.06 × 106

7.46 × 104

ATCC 27,853

mAb

pAb

4.10 ± 0.39 × 104

2.04 × 103

ATCC 27,853

pAb

mAb

4.56 ± 1.11 × 105

5.78 × 103

ATCC 27,853

rAb

pAb

7.01 ± 0.79 × 104

7.85 × 103

ATCC 27,853

rAb

mAb

8.21 ± 0.95 × 105

6.30 × 104

ATCC BAA-2108

mAb

pAb

9.19 ± 0.56 × 104

3.79 × 103

ATCC BAA-2108

pAb

mAb

1.20 ± 0.04 × 105

7.70 × 102

ATCC BAA-2108

rAb

pAb

1.39 ± 0.22 × 104

2.30 × 102

ATCC BAA-2108

rAb

mAb

1.63 ± 0.17 × 105

1.84 × 104