Skip to main content

Table 1 Half maximal effective concentration (EC50) and limit of detection (LOD) values of antibodies that were determined from the titration curves of indirect ELISA. n.d. = not detected

From: Generation of a recombinant antibody for sensitive detection of Pseudomonas aeruginosa

P. aeruginosa strain

Antibody

EC50 (CFU/mL)

LOD (CFU/mL)

UCBPP-PA14

Polyclonal antibody (pAb)

3.08 ± 0.31 × 107

2.92 × 106

UCBPP-PA14

Monoclonal antibody (mAb)

7.46 ± 3.27 × 106

4.69 × 106

UCBPP-PA14

Recombinant antibody (rAb)

n.d

n.d

ATCC 27,853

pAb

5.03 ± 0.98 × 104

3.50 × 102

ATCC 27,853

mAb

2.77 ± 0.37 × 106

4.01 × 105

ATCC 27,853

rAb

1.01 ± 0.28 × 106

2.43 × 105

ATCC BAA-2108

pAb

1.30 ± 0.08 × 105

4.42 × 105

ATCC BAA-2108

mAb

2.15 ± 0.27 × 106

1.37 × 105

ATCC BAA-2108

rAb

2.91 ± 0.30 × 106

7.62 × 105